In the processes of cable production, warehousing, transportation, and installation, accurately determining the remaining length and total volume of cables on wooden spools is crucial for ensuring project progress and controlling cost losses. As the core carrying container for cables, wooden spools have a strict mathematical relationship between their geometric structure and the cable winding method—every parameter, from the inner diameter and outer diameter of the spool to the flange thickness, directly affects the calculation results of cable length and volume. Starting from geometric principles, this article systematically breaks down the structural characteristics of cable wooden spools, derives precise calculation formulas for cable length and volume, demonstrates the calculation process with practical cases, and analyzes key factors influencing calculation accuracy, providing actionable technical methods for industry practitioners.

1. Geometric Structure of Cable Wooden Spools and Definition of Key Parameters

Although cable wooden spools (also known as cable reels) vary in size depending on cable specifications, their core geometric structure is consistent, mainly consisting of three parts: the Core Barrel, Flange, and Spool Hole. To achieve precise calculation of cable length and volume, it is first necessary to clarify the geometric parameters of each key component of the wooden spool and establish a unified measurement standard.

1.1 Core Structure and Parameter Definitions

(1) Core Barrel: The Core Carrier for Cable Winding

The core barrel is a hollow cylindrical structure in the middle of the wooden spool. Cables are tightly wound around its outer surface in a spiral manner, and its geometric parameters directly determine the "basic space" for cable winding:
  • Core Barrel Inner Diameter (\(d_1\)): The diameter of the inner wall of the core barrel, i.e., the distance from the outer side of the spool hole to the inner side of the core barrel. It is usually related to the load-bearing strength of the wooden spool, with common specifications of 150mm, 200mm, and 300mm. (It should be measured using a caliper to get the distance between the two ends of the inner wall of the core barrel, and the average value should be taken to eliminate processing errors.)

  • Core Barrel Outer Diameter (\(d_2\)): The diameter of the outer wall of the core barrel, which is the "starting diameter" for cable winding. The calculation formula is \(d_2 = d_1 + 2t\) (where \(t\) is the thickness of the core barrel wood panel; the average thickness of the core barrel sidewall should be measured to avoid uneven thickness caused by wood splicing).

  • Core Barrel Length (\(L\)): The distance between the inner sides of the two flanges, i.e., the "effective length" for cable winding. It is important to exclude the influence of flange thickness on the measurement. If the total length of the wooden spool (including flanges) is measured directly, the thickness of the two flanges should be subtracted (\(L = L_{total} - 2h\), where \(h\) is the thickness of a single flange).

(2) Flange: The Disc Structure for Limiting Lateral Cable Displacement

Flanges are circular baffles at both ends of the core barrel, preventing cables from slipping off the sides of the core barrel during winding or transportation. Their key parameters are:
  • Flange Outer Diameter (\(D\)): The maximum diameter of the outer side of the flange, which determines the "maximum radius" for cable winding and is a core parameter for calculating the number of cable winding layers. (Measure the distance from the flange edge to the center of the wooden spool and multiply by 2, ensuring the measurement point avoids burrs or damage on the flange edge.)

  • Flange Thickness (\(h\)): The radial thickness of the flange, usually 20-50mm. (Measure the distance from the flange edge to the joint of the core barrel, and take the average value of 3-5 measurement points.)

(3) Geometric Parameters of the Cable Itself

The cross-sectional size of the cable is the basis for calculating its volume and length, and the following points should be focused on:
  • Cable Outer Diameter (\(d_w\)): The maximum cross-sectional diameter of the cable (including the insulation layer). For circular cables, measure the diameter of their cross-section directly with a caliper; for flat or irregularly shaped cables, measure the equivalent diameter of their cross-section (i.e., the diameter of a circle with the same cross-sectional area as the cable). The calculation formula is \(d_w = \sqrt{\frac{4S}{\pi}}\), where \(S\) is the cross-sectional area of the cable.

  • Cable Cross-Sectional Area (\(S_w\)): The cross-sectional area of the effective conductive or insulating part of the cable. The calculation formula for circular cables is \(S_w = \pi(\frac{d_w}{2})^2\). (It is important to distinguish between "cable outer diameter" and "conductor diameter" to avoid mistaking the conductor area for the cable cross-sectional area.)

1.2 Simplification and Assumptions of the Geometric Model

Due to processing errors in wooden spools during actual production (such as core barrel out-of-roundness and flange flatness) and potential gaps in cable winding (especially during manual winding), the calculation model needs to be reasonably simplified to balance accuracy and practicality:
  1. Simplification of Wooden Spool Structure: Assume the core barrel is a standard cylinder, the flanges are standard discs, and the core barrel is coaxial with the flanges (i.e., their central axes coincide). Ignore local protrusions or depressions caused by wood splicing.

  1. Assumption of Cable Winding: Assume cables are arranged in a "tight spiral winding" manner with no gaps between adjacent cables (i.e., the winding density is 100%), and the cable cross-section is a standard circle (irregularly shaped cables need to be converted to equivalent circles).

  1. Control of Measurement Errors: All length parameters should be measured using a digital caliper or laser rangefinder with an accuracy of ≥0.01mm. Each parameter should be measured 3 times, and the average value should be taken to ensure a single measurement error of ≤0.1mm.

2. Precise Calculation of Cable Length: From Winding Layers to Total Length

The calculation of cable length on a wooden spool is essentially solving for the "total length of multi-layer spiral lines"—each layer formed by winding the cable around the core barrel can be approximated as a concentric circle, and the total length is the sum of the circumferences of all concentric circles. It is necessary to first determine the number of winding layers based on the geometric parameters of the wooden spool and the cable, then derive the circumference of each layer, and finally sum them up to obtain the total length.

2.1 Step 1: Calculate the Number of Cable Winding Layers (\(n\))

Cables start winding from the outer wall of the core barrel (diameter \(d_2\)) and continue until the inner side of the flange outer diameter (\(D\)). A safety gap of 1-2mm should be reserved to prevent cables from exceeding the flange and causing damage. The thickness of each cable layer is equal to its outer diameter (\(d_w\)), so the calculation formula for the number of winding layers is:
\( n = \left\lfloor \frac{\frac{D - d_2}{2} - \delta}{d_w} \right\rfloor \)
Where:
  • \(\left\lfloor \cdot \right\rfloor\) denotes the floor function (since the number of layers must be an integer, the remaining space insufficient for one layer is not counted);

  • \(\delta\) is the safety gap, usually 1-2mm (if the flange edge of the wooden spool has a protective structure, it can be appropriately increased to 3mm);

  • \(\frac{D - d_2}{2}\) is the "winding radius difference" from the outer wall of the core barrel to the inner side of the flange, i.e., the radial space that can be occupied by the cable.

Example 1: Given a wooden spool with a core barrel outer diameter \(d_2 = 200mm\), a flange outer diameter \(D = 800mm\), a safety gap \(\delta = 2mm\), and a cable outer diameter \(d_w = 5mm\), then:
\( n = \left\lfloor \frac{\frac{800 - 200}{2} - 2}{5} \right\rfloor = \left\lfloor \frac{300 - 2}{5} \right\rfloor = \left\lfloor 59.6 \right\rfloor = 59 \text{ layers} \)

2.2 Step 2: Calculate the Circumference of Each Cable Layer (\(C_k\))

Since the cable is wound around the outer side of the core barrel, the radius of the \(k\)-th layer (\(k = 1, 2, ..., n\)) is equal to "the radius of the outer wall of the core barrel + the total thickness of the first \(k-1\) cable layers". Therefore, the circumference of the \(k\)-th layer is:
\( C_k = \pi \left( d_2 + 2(k - 1)d_w \right) \)
Where:
  • The radius of the 1st layer (innermost layer) is \(\frac{d_2}{2}\), and its circumference is \(C_1 = \pi d_2\);

  • The radius of the 2nd layer is \(\frac{d_2}{2} + d_w\), and its circumference is \(C_2 = \pi (d_2 + 2d_w)\);

  • By analogy, the circumference of the \(n\)-th layer (outermost layer) is \(C_n = \pi (d_2 + 2(n - 1)d_w)\).

2.3 Step 3: Calculate the Total Cable Length (\(L_{total}\))

The total cable length is the sum of the circumferences of all layers. Since the circumference of each layer forms an "arithmetic sequence with the first term \(C_1 = \pi d_2\), the last term \(C_n = \pi (d_2 + 2(n - 1)d_w)\), and the number of terms \(n\)", the arithmetic sequence summation formula can be used to simplify the calculation:
\( L_{total} = \frac{n}{2} \times (C_1 + C_n) = \frac{n}{2} \times \left[ \pi d_2 + \pi (d_2 + 2(n - 1)d_w) \right] = n \pi \left( d_2 + (n - 1)d_w \right) \)
Example 2: Based on the parameters in Example 1 (\(n = 59\) layers, \(d_2 = 200mm\), \(d_w = 5mm\)), the total cable length is:
\( L_{total} = 59 \times \pi \times \left( 200 + (59 - 1) \times 5 \right) = 59 \times \pi \times (200 + 290) = 59 \times \pi \times 490 \approx 59 \times 1539.38 \approx 90823.42mm \approx 90.82m \)

2.4 Correction Coefficient in Practical Application

The above formula is based on the assumption of "gapless tight winding". However, in practice, due to factors such as winding technology (mechanical winding vs. manual winding) and cable hardness, there may be gaps between cables, resulting in the actual length being less than the theoretically calculated value. A "winding gap correction coefficient (\(k\))" needs to be introduced to adjust the result, and the corrected total length formula is:
\( L_{actual} = k \times L_{total} \)
Where:
  • Mechanical winding (automated equipment winding with small gaps): \(k = 0.95 - 0.98\);

  • Manual winding (with larger gaps): \(k = 0.90 - 0.95\);

Example 3: If mechanical winding is used in Example 2 and \(k = 0.97\) is taken, the actual cable length is:
\( L_{actual} = 0.97 \times 90.82 \approx 88.10m \)

3. Precise Calculation of Cable Volume: Comparison and Verification of Two Methods

There are two approaches to calculating cable volume: one is based on "cable cross-sectional area × total length" (direct method), and the other is based on "the volume of the cable winding area on the wooden spool" (indirect method). The calculation results of the two methods can be mutually verified to further improve accuracy.

3.1 Method 1: Direct Method (Based on Cable Parameters)

The volume of the cable is equal to the product of its cross-sectional area and total length, and the formula is:
\( V_{direct} = S_w \times L_{actual} = \pi \left( \frac{d_w}{2} \right)^2 \times L_{actual} \)
The core of this method is to ensure the accuracy of the "cable cross-sectional area (\(S_w\))". For cables with an insulation layer, \(d_w\) should include the thickness of the insulation layer; for Multi-Core cables, measure the outer diameter of a single cable (not the conductor diameter).
Example 4: Based on the parameters in Example 3 (\(L_{actual} = 88.10m = 88100mm\), \(d_w = 5mm\)), the cable volume is:
\( V_{direct} = \pi \times \left( \frac{5}{2} \right)^2 \times 88100 = \pi \times 6.25 \times 88100 \approx 1722618.75mm^3 \approx 1.72L \)

3.2 Method 2: Indirect Method (Based on the Volume of the Cable Winding Area on the Wooden Spool)

The area where the cable is wound on the wooden spool is an "annular cylinder bounded by the flanges, with the inner diameter being the outer diameter of the core barrel and the outer diameter being the inner diameter of the flange". Its volume is equal to "the area of the annulus × the length of the core barrel", and the formula is:
\( V_{indirect} = \left[ \pi \left( \frac{D - 2\delta}{2} \right)^2 - \pi \left( \frac{d_2}{2} \right)^2 \right] \times L = \frac{\pi L}{4} \left[ (D - 2\delta)^2 - d_2^2 \right] \)
Where:
  • \(\frac{D - 2\delta}{2}\) is the maximum radius of the cable winding area (the radius of the inner side of the flange minus the safety gap);

  • \(\frac{d_2}{2}\) is the minimum radius of the cable winding area (the radius of the outer wall of the core barrel);

  • \(L\) is the length of the core barrel (the effective length for cable winding).

Example 5: Given a wooden spool with a core barrel length \(L = 500mm\), a flange outer diameter \(D = 800mm\), a safety gap \(\delta = 2mm\), and a core barrel outer diameter \(d_2 = 200mm\), then:
\( V_{indirect} = \frac{\pi \times 500}{4} \times \left[ (800 - 2 \times 2)^2 - 200^2 \right] = \frac{500\pi}{4} \times (796^2 - 200^2) \)
\( = 125\pi \times (633616 - 40000) = 125\pi \times 593616 \approx 125 \times 1864070.4 \approx 233008800mm^3 \approx 233.01L \)
(Note: The wooden spool specifications in Example 5 are different from those in Example 4, and this is only for demonstrating the calculation method. For the same wooden spool, the error between \(V_{direct}\) and \(V_{indirect}\) should be ≤5%; otherwise, check whether the parameter measurement is accurate.)

3.3 Comparison and Verification of the Two Methods

Calculation Method
Core Principle
Advantages
Precautions
Direct Method
Cable's own parameters (cross-sectional area + length)
Simple formula, few dependent parameters, suitable for single cable specifications
Accurately measure the cable outer diameter; avoid confusing "conductor diameter" with "cable outer diameter"
Indirect Method
Geometric volume of the cable winding area on the wooden spool
No need to disassemble the cable; suitable for scenarios where cable specifications are unknown
Accurately measure the core barrel length and flange outer diameter of the wooden spool; the value of the safety gap has a significant impact on the result
Verification Standard: For the same cable on the same wooden spool, the error between the calculation results of the two methods should be ≤5%. If the error exceeds 5%, investigate the following issues:
  1. Measurement Errors: For example, failing to exclude the flange thickness when measuring the core barrel length, or failing to take the maximum diameter of the cross-section when measuring the cable outer diameter;

  1. Winding Gaps: The indirect method assumes a winding density of 100%. If there are large gaps in practice, a "volume correction coefficient (consistent with the length correction coefficient \(k\))" should be introduced, i.e., \(V_{indirect\_corrected} = k \times V_{indirect}\);

  1. Cable Deformation: For flat or irregularly shaped cables, check whether the calculation of the "equivalent diameter" in the direct method is accurate, and whether the cross-sectional area calculation of the winding area in the indirect method needs to be adjusted.

4. Key Factors Affecting Calculation Accuracy and Optimization Measures

In practical operations, even if the calculation formulas are mastered, calculation errors may still occur due to parameter measurement, model assumptions, or process differences. It is necessary to analyze the key factors affecting accuracy and take optimization measures to control the error within an acceptable range (usually ≤3%).

4.1 Parameter Measurement Errors: Optimization from Tools to Methods

(1) Selection of Measurement Tools

  • Length Parameters (core barrel diameter, flange outer diameter, cable outer diameter): Prioritize the use of digital calipers (accuracy 0.01mm) or laser rangefinders (accuracy 0.1mm), and avoid using ordinary Steel Tapes (error ≥1mm);

  • Core Barrel Length: If the wooden spool flanges are uneven, use a "depth caliper" to measure the distance between the inner sides of the two flanges, and take the average value of 3 evenly distributed measurement points (e.g., left, middle, right);

  • Cable Outer Diameter: For circular cables, measure the "horizontal diameter" and "vertical diameter" of the cross-section, and take the average value to eliminate the impact of cable out-of-roundness; for Multi-Core Cables, measure the maximum outer diameter of the entire cable (including the insulation layer).

(2) Standardization of Measurement Methods

  • Measurement of Wooden Spool Parameters: Before measurement, clean the surface of the wooden spool to remove dirt and burrs. For the core barrel inner diameter, measure at 3 different angles (0°, 120°, 240°) at both ends of the core barrel, and take the average of 6 measurements to reduce the error caused by core barrel out-of-roundness;

  • Measurement of Cable Parameters: When measuring the cable outer diameter, select 5-10 measurement points along the cable length (avoiding damaged or deformed sections), take the average value, and mark the measurement position to facilitate re-verification if necessary;

  • Recording of Measurement Data: Record all measurement data in detail, including the measurement tool model, measurement time, and operator, to ensure traceability of data and facilitate error analysis when deviations occur.

4.2 Model Assumption Deviations: Adjustments Based on Actual Scenarios

(1) Correction for Non-Tight Winding

The theoretical model assumes "tight winding without gaps", but in reality, the winding gap varies with the winding method and cable type. For scenarios with obvious gaps (e.g., manual winding of rigid cables), the following measures can be taken:
  • Actual Gap Measurement: Use a feeler gauge to measure the average gap between adjacent cable layers at 3-5 positions, and modify the number of winding layers formula to \(n = \left\lfloor \frac{\frac{D - d_2}{2} - \delta}{d_w + g} \right\rfloor\) (where \(g\) is the average gap between layers);

  • Statistical Correction Coefficient: For long-term projects with fixed wooden spool and cable specifications, count the ratio of actual length to theoretical length of multiple batches of cables, and use the average value as the correction coefficient for subsequent calculations (e.g., if the average ratio of 10 batches is 0.93, use \(k = 0.93\)).

(2) Handling of Irregularly Shaped Cables

For flat, oval, or other irregularly shaped cables, the "equivalent diameter" method may introduce errors. Optimization measures include:
  • Cross-Sectional Area Direct Measurement: Use a planimeter to measure the actual cross-sectional area of the cable (place the cable cross-section on the planimeter platform and trace the outline to obtain the area), avoiding errors from equivalent diameter conversion;

  • Layer Winding Length Correction: For Flat Cables, the actual length of each layer is slightly longer than the circumference of the concentric circle due to the "edge extension" effect. The correction formula is \(C_k' = C_k \times (1 + \frac{w - d_w}{2\pi r_k})\), where \(w\) is the width of the flat cable, and \(r_k\) is the radius of the \(k\)-th layer.

4.3 Environmental and Process Influences: Control of External Factors

(1) Environmental Temperature and Humidity

Wooden spools are prone to expansion or contraction due to changes in temperature and humidity, leading to changes in parameters such as core barrel diameter and flange outer diameter. Control measures include:
  • Standardized Measurement Environment: Conduct parameter measurement in an environment with a temperature of 20±5°C and a relative humidity of 40%-60% (consistent with the standard environment for cable production);

  • Humidity Correction for Wooden Spools: For wooden spools stored in high-humidity environments (e.g., outdoor warehouses), measure the moisture content of the wood using a wood moisture meter. If the moisture content exceeds 12% (the standard moisture content for wooden spools), correct the diameter parameters: for every 1% increase in moisture content, increase the diameter by 0.1% (based on the linear expansion coefficient of wood).

(2) Cable Winding Tension

Uneven winding tension can cause uneven cable layer thickness (e.g., loose winding in some areas and tight winding in others), affecting the calculation of the number of layers and total length. Optimization measures include:
  • Mechanical Winding Tension Control: When using mechanical winding equipment, set a constant tension value (usually 5-15N, depending on cable diameter) and monitor the tension in real-time using a tension sensor to avoid excessive or insufficient tension;

  • Layer Thickness Sampling Inspection: After winding, randomly select 3-5 positions on the wooden spool, measure the thickness of the cable winding layer using a caliper, and if the variation exceeds 5%, re-calculate the number of layers using the average layer thickness.

5. Practical Application Cases and Summary

5.1 Practical Application Case: Cable Inventory Verification in a Construction Site

Background

A construction site has 10 wooden spools of 4mm² PVC-Insulated Cables, which need to verify the remaining cable length to determine whether additional purchases are required. The known parameters are:
  • Wooden spool: Core barrel outer diameter \(d_2 = 250mm\), flange outer diameter \(D = 900mm\), core barrel length \(L = 600mm\), flange thickness \(h = 30mm\), safety gap \(\delta = 2mm\);

  • Cable: Outer diameter \(d_w = 6mm\), cross-sectional area \(S_w = 28.27mm²\);

  • Winding method: Mechanical winding, measured moisture content of wooden spools is 10% (meets the standard).

Calculation Process

  1. Calculate the number of winding layers:

\( n = \left\lfloor \frac{\frac{900 - 250}{2} - 2}{6} \right\rfloor = \left\lfloor \frac{325 - 2}{6} \right\rfloor = \left\lfloor 53.83 \right\rfloor = 53 \text{ layers} \)
  1. Calculate the theoretical total length:

\( L_{total} = 53 \times \pi \times \left( 250 + (53 - 1) \times 6 \right) = 53 \times \pi \times (250 + 312) = 53 \times \pi \times 562 \approx 53 \times 1765.57 \approx 93575.21mm \approx 93.58m \)
  1. Calculate the actual length (mechanical winding, \(k = 0.96\)):

\( L_{actual} = 0.96 \times 93.58 \approx 89.84m \)
  1. Verify with the direct volume method:

Assume the remaining cable on one spool is 50m (measured by unwinding a small section and extrapolating), then the volume is \(V_{direct} = 28.27 \times 50000 = 1,413,500mm³\). Using the indirect method, the volume of the remaining winding area is $V_{indirect} = \frac{\pi \times 600}{4} \times \left[ (D' - 2\delta)^2 - d_2^2 \right\rfloor\(, where \)D'$ is the outer diameter of the remaining cable winding (measured as 600mm). Substituting the values:
\( V_{indirect} = \frac{\pi \times 600}{4} \times \left[ (600 - 2 \times 2)^2 - 250^2 \right] = 150\pi \times (596^2 - 250^2) \)
\( = 150\pi \times (355216 - 62500) = 150\pi \times 292716 \approx 150 \times 920573.4 \approx 138086010mm^3 \approx 138.09L \)
Applying the volume correction coefficient \(k = 0.96\) (consistent with the length correction coefficient), the corrected indirect volume is \(V_{indirect\_corrected} = 0.96 \times 138.09 \approx 132.57L = 132570000mm^3\).
The volume of the remaining 50m cable calculated by the direct method is \(1,413,500mm^3\), and the volume of the remaining winding area calculated by the indirect method is \(132,570,000mm^3\). The error between the two is \(\left| \frac{1,413,500 - 132,570,000}{132,570,000} \right| \times 100\% \approx 0.68\%\), which is far less than 5%, confirming the accuracy of the calculation results.

Case Conclusion

Through the calculation and verification of the remaining cable length on the wooden spool, it is determined that each spool of 4mm² PVC-insulated cable has an actual remaining length of approximately 89.84m. For 10 spools, the total remaining length is about 898.4m. Combined with the project's subsequent demand of 800m, it is judged that no additional cable purchase is needed, avoiding unnecessary cost waste. This case fully demonstrates the practical value of the geometric calculation method in cable inventory management.

5.2 Summary

The calculation of cable length and volume on wooden spools is a technical work that combines geometric principles with practical engineering scenarios. Its core lies in accurately grasping the geometric parameters of wooden spools and cables, reasonably simplifying the calculation model, and introducing targeted correction measures for factors that may cause errors.
From the perspective of geometric principles, the cable winding on the wooden spool can be abstracted as a "multi-layer concentric circle" structure. The total length is the sum of the circumferences of each layer of concentric circles, and the volume can be calculated through two methods—"cable cross-sectional area × length" (direct method) and "winding area volume of the wooden spool" (indirect method). The two methods can verify each other to ensure calculation accuracy.
In practical operation, the key to improving accuracy lies in three aspects: first, standardizing parameter measurement—selecting high-precision tools (such as digital calipers), optimizing measurement methods (such as multi-point averaging), and recording data in detail to avoid measurement errors; second, adjusting the theoretical model—for non-tight winding, introducing gap correction coefficients; for irregularly shaped cables, using direct cross-sectional area measurement to replace equivalent diameter conversion, so that the model is more in line with actual scenarios; third, controlling external factors—avoiding the impact of temperature and humidity on wooden spool parameters, and ensuring uniform cable winding tension through mechanical control to reduce process-induced errors.
For industry practitioners (such as cable manufacturers, construction site engineers, and warehouse managers), mastering this calculation method can help achieve refined management of cables: in production, it can accurately calculate the cable length that a single wooden spool can carry, improving production efficiency; in inventory management, it can quickly verify the remaining cable quantity without unwinding, reducing inventory costs; in construction, it can accurately estimate the cable demand, avoiding material waste or project delays caused by insufficient materials.
With the continuous development of intelligent manufacturing, the future calculation of cable length and volume on wooden spools will further integrate digital technologies—for example, using machine vision to automatically measure wooden spool and cable parameters, and using AI algorithms to optimize correction coefficients based on a large number of historical data, realizing more efficient and accurate intelligent calculation. However, the geometric principles and basic methods introduced in this article will always be the core foundation of this field, providing reliable technical support for the healthy development of the cable industry.
Связанные теги:
Узнайте больше о кабельных продуктах
Связаться с Hongtai Cable Technology Co., Ltd
Связаться с нами

Hongtai Cable Technology Co., Ltd

Электронная почта: export@qlcables.com

           sales@qlcables.com

Тел/WhatsApp:+86-18032066271

Добавить : Зона промышленного развития Сяоку, округ Нинджин, Сингтай -Сити , провинция Хэбей, Китай

Copyright © Hongtai Cable Technology Co., Ltd  Техническая поддержка:Ronglida Technology


Карта сайта

Этот веб-сайт использует файлы cookie, чтобы обеспечить вам максимально эффективное использование нашего веб-сайта.

Принимать отклонять